The use of energy-saving ceiling fans requires regular maintenance. In addition to ensuring the stability of structural components, it is also important to ensure the proper operation of the motor. This article takes the mainstream asynchronous reduction motor and permanent magnet synchronous motor as examples to introduce the daily maintenance from before motor startup to motor operation.

  1. Before motor startup: Before starting the energy-saving ceiling fan motor, the staff needs to check the power supply to determine if there is electricity and if the voltage is stable. Unstable voltage can cause significant damage to the motor. Additionally, it is necessary to ensure the normal functioning of the motor starter by checking the integrity, good connections, and correct wiring of starter components. It is particularly important to pay attention to the motor itself. This requires inspecting the motor's terminal board, checking the wiring connections, and ensuring that the fuse specifications used by the motor match its working specifications. Lastly, before motor startup, it is important to check the motor's working environment and location, remove debris and dust near the motor, and ensure that the motor operates in a good working environment. Of course, most of these inspections are usually conducted by the fan manufacturer during installation and after-sales service.

  2. During motor startup: When starting a large ceiling fan, if the motor does not respond (i.e., the fan does not run) after turning on the power, the motor power should be immediately disconnected. During the initial startup, it is necessary to check and observe the operation of the motor's transmission device. If any abnormal conditions occur, the motor power should be immediately cut off, and troubleshooting should be carried out. Only after confirming that the fault has been resolved, the motor can be started again. It is important to focus on the previously faulty parts. When starting the motor, follow the motor's operating instructions and operate the motor step by step. For example, when starting the motor, first place the motor switch in the startup position. Once the motor enters a stable working state, switch the motor to the running position.

  3. During motor operation: During motor operation, relevant personnel needs to constantly monitor the motor's operating status. It is particularly important to monitor the motor's temperature when it is running. To prevent the motor from operating at high temperatures, which can easily occur under heavy load, personnel should monitor the motor's temperature to ensure it does not exceed the highest design temperature for normal use. The temperature can be checked by touching the motor with hands or by using a water droplet test on the motor's casing. Observing the evaporation process of the water droplets can provide an indication. The most accurate method is to use a thermometer to measure the motor's temperature. If the motor's temperature is found to be too high during operation, it should be immediately stopped, and the power should be disconnected until the technical personnel has resolved the motor fault before resuming use.

Finally, if the motor experiences severe vibrations, abnormal noises, or a pungent burnt smell during operation, it should be immediately stopped, and the motor should be inspected or contacted with the fan manufacturer for on-site testing and maintenance.

Related News
Read More >>
How many blades are good for HVLS industrial fans? How many blades are good for HVLS industrial fans?
Jun .30.2023
The HVIST fan was invented by a joint venture between a US and a Chinese company in 1999. After almost 20 years of development, various industrial fans with different numbers of blades have emerged. Currently, domestically and internationally, industrial fans mainly come in three-blade, four-blade, five-blade, six-blade, and eight-blade configurations. In theory, the more blades a fan has, the greater the airflow. However, since industrial fans are generally larger in size, more blades also mean more weight and increased safety risks. Therefore, it is necessary to strike a good balance between airflow and quality. Currently, industrial fans with five or six blades are most popular on the market. These two types are also the main products promoted abroad and have been market-certified for over a decade. As long as manufacturers strictly require high quality and safety for the blades, they can meet market demand.
Large fans in the indoor basketball hall improve ventilation and cooling Large fans in the indoor basketball hall improve ventilation and cooling
Jun .27.2023
With the promotion of nationwide fitness, various communities have built indoor basketball courts of different sizes. However, the large span, high height, and relatively sealed building structure of basketball courts pose great challenges to ventilation and cooling. In recent years, many venue constructors have found that large fans (big ceiling fans) can perfectly solve the ventilation and cooling problems, which are tricky for indoor basketball courts.
Principles to be followed in designing industrial large fan blades Principles to be followed in designing industrial large fan blades
Jun .27.2023
Industrial large fans have been imported into China from abroad, and batches of industrial fan manufacturers have been continuously researching, developing, and producing a full range of large industrial fan series products suitable for various environmental improvements in China. High-quality large fans are often built on good materials and unique advanced designs. The fan blades of industrial large fans are made of 5052 aviation aluminum, and unique blade designs can maximize the advantages of large fans and meet the needs of different users. When designing fan blades, industrial fan manufacturers need to follow certain principles.
pop_close
pop_main
Stay In The Know
In order to know your requirements well and offer the suitable solution for you, could you please fill in the following information?